5% off First Purchase
Sale!

HYD-RTX70-DD Hydraulic Motor Pump | 18.5 GPM 2900 PSI

0 review
Rated 5 out of 5

Original price was: $5,462.51.Current price is: $2,719.00.

HYD-RTX70-DD — Hydraulic motor-driven RTX70 triplex pump delivering 18.5 GPM at 2900 PSI in a compact, alignment-friendly direct-drive package.

Availability: 1 in stock

Secure Checkout | Transparent Pricing | No Hidden Fees

Overview

  • HYD-RTX70-DD is a compact, belt-free hydraulic drive package that directly couples a
    low-speed/high-torque (LSHT) hydraulic motor to an Annovi Reverberi RTX70 high-pressure
    triplex plunger pump on a rigid, alignment-stable base.
  • Delivers dependable cleaning power while keeping shaft centerlines true to protect bearings and seal packs.
  • Built in Modena, Italy by Annovi Reverberi—pump quality leader since 1958.
  • This build is targeted for approximately 18.5 GPM (≈70 L/min) at 2900 PSI (≈200 bar) in the
    1000–1450 RPM operating window.
  • Ideal for single- or dual-gun washdown and process rinse without belt dust, guard bulk, or alignment drift.
  • Ships installer-friendly with clear access to the coupling, easy-view oil sight glass, and a
    vented dipstick; pump is pre-filled with oil for quick pre-start checks.

HYD-RTX70-DD Hydraulic Motor & Circuit

  • Uses a displacement-matched LSHT gerotor/geroler-type hydraulic motor (brand varies) sized
    to reach rated pump speed and torque at pressure.
  • Interfaces with standard mobile or plant circuits via pressure and return ports typically
    SAE-12 (3/4″ ORB), with an auxiliary case-drain port typically
    SAE-8 (1/2″ ORB) when required by the chosen motor build.
  • Observe A/B port orientation for correct rotation; route the case drain above reservoir oil level to prevent
    aeration.
  • Size hoses generously and respect bend radii to avoid restriction and heat build-up.
  • Protect the circuit with upstream relief valves suitable for 200-bar service and specify
    10–25 μm return filtration with an adequate β-rating.
  • Size the hydraulic reservoir for heat rejection (practical rule: 2–3× total system flow) and
    add an oil cooler for hot climates, prolonged bypass, or continuous-duty cycles.

HYD-RTX70-DD Pump Ports & Water-Side Plumbing

  • RTX70 manifolds are typically 1-1/4″ female BSPP inlet and
    1/2″ female BSPP discharge; adapters to NPT are readily available.
  • Keep the suction run short, straight, and oversize from a flooded supply.
  • Include a coarse inlet strainer and use anti-collapse suction hose to preserve volumetric efficiency and
    minimize cavitation.
  • Use an adjustable unloader matched to RTX70 duty to hold working pressure while safely
    bypassing flow to tank.
  • Add a high-pressure relief valve and a glycerin-filled pressure gauge for
    commissioning and diagnostics.
  • Include a thermal relief valve on the bypass loop to protect seals during extended
    gun-closed or bypass operation.

Integration Checklist

  • Match motor displacement and available hydraulic flow to achieve the required pump RPM at
    ≈2900 PSI.
  • Verify upstream relief settings and confirm return filtration, reservoir volume, and cooling capacity for
    the duty cycle.
  • Provide a case drain if specified by the motor manufacturer and route it above tank oil level.
  • Select nozzle orifices for the desired 18.5 GPM @ 2900 PSI working point and never
    overspeed the pump.
  • Plan a low-pressure recirculation path for prolonged bypass to control heat.
  • Schedule periodic torque checks on head, manifold, base, and coupling fasteners to preserve alignment and
    seal life.

Why Direct Drive

  • Smooth torque transfer for stable pressure and calm trigger cycling.
  • Compact footprint with predictable hose routing for repeatable OEM builds.
  • Alignment-stable geometry reduces bearing side-load and extends seal life.
  • No belt tensioning, no belt dust, and less guard bulk for cleaner installs.
  • Open access to coupling, sight glass, dipstick, and fasteners for fast single-tech PM.

HYD-RTX70-DD Typical Applications

  • Tug-boat and dock washdown, aquaculture pens, and marina sanitation.
  • Municipal fleets, sanitation/public-works rigs, and jetter/vac-truck support.
  • Food & beverage plants and packaging rooms (observe local hygienic standards).
  • Agriculture and ranch equipment wash and fertilizer/barn cleanup.
  • Conveyor systems, parts-cleaning cells, and general plant maintenance carts.
  • Work-truck skids, enclosed van bodies, rental fleets, and contractor rigs with onboard hydraulic power.

HYD-RTX70-DD Ownership, Warranty & Key Details

  • Manufacturer & origin: Annovi Reverberi, Modena, Italy—leader in high-pressure
    pump quality since 1958.
  • Water performance: ≈18.5 GPM (≈70 L/min) @ ≈2900 PSI (≈200 bar) in the 1000–1450 RPM band.
  • Hydraulic motor: LSHT gerotor/geroler type; hydraulic ports typically SAE-12 ORB
    pressure/return with SAE-8 ORB case drain (verify on selected motor).
  • Pump ports: 1-1/4″ F-BSPP inlet and 1/2″ F-BSPP outlet; adapt to NPT as needed.
  • Included with pump: factory oil fill, sight glass, and vented dipstick for quick
    commissioning.
  • Warranty: 5-year limited, conditional warranty—proper installation (hydraulic and water),
    filtration, lubrication, and operation within published limits are required; seals and valves are treated
    as consumable wear items.
  • Benefits: compact direct drive, smooth pressure response, predictable hose routing, and
    fast single-tech service for demanding industrial cleaning systems.
Weight 96 lbs
Dimensions 16.02 × 21.97 × 7.72 in

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top

Request a Quote

5 % Coupon

RRA4G30N-VRT-PKG Pressure Pump
First Time Purchase

5% Off

Welcome to WSHPWR

Unsubscribe anytime. We respect your privacy.