RGAHW4G40HN Hot Water Pump: 4.0 GPM at 4000 PSI, 1750 RPM
The RGAHW4G40HN is the hot water version of the Annovi Reverberi RGA pump, built for burner-equipped machines that cut through grease and oil with heat as well as pressure. It is rated for 4.0 GPM at 4000 PSI at 1750 RPM, with water up to 180°F, and is backed by a 5-year AR warranty.
The nickel-plated brass head adds corrosion resistance, and the 24 mm solid shaft is ready for belt drive, gearbox or flexible coupler installations.
| Specification | Value |
|---|---|
| Model | RGAHW4G40HN |
| Flow | 4.0 GPM |
| Max pressure | 4,000 PSI |
| Speed | 1750 RPM |
| Power required | 11 EBHP |
| Shaft | 24 mm solid |
| Inlet / outlet | 1/2″ F / 3/8″ F |
| Plunger diameter / stroke | 18 mm / 12.2 mm |
| Oil capacity | 32 oz |
| Max water temperature | 180°F |
Why a Dedicated Hot Water Pump
Standard seals soften as inlet water warms, and a cold water pump on a heated system loses pressure and leaks early. The RGAHW4G40HN is built for warm supply water up to 180°F, so it holds pressure through a full shift on a hot water machine.
Before You Install
- This pump needs 11.0 EBHP (4.0 GPM x 4000 PSI / 1457). Size the motor or engine with headroom above that figure.
- The pump sits ahead of the burner, so it only sees supply water, never heated discharge. Keep inlet water at or below 180°F.
- Fit a thermal relief valve such as the TPP140-1/4A on the outlet. Water circulating in bypass heats up fast when the trigger wand is closed.
- Keep the inlet fed and unrestricted, with a 50 mesh (minimum) line strainer. A starved pump wears out plungers and seals fast.
Our article on burner thermostats in hot water systems covers the controls that keep the rest of the machine within its temperature limits.
Ready-to-Run Option
Need the pump already mounted to a motor? The RGAHW4G40HN-E10F pairs this pump with a 10 HP electric motor. For cold water service, the RGA4G40HN-E10F unit runs the same 4.0 GPM at 4000 PSI.
Care and Maintenance
- Change the oil after the first 50 hours, then every 500 hours or every 3 to 5 months, whichever comes first. Milky oil means water is getting past the seals.
- Check the inlet strainer at every service. Scale and debris from a heated system wear seals quickly.
- Never store the pump with water inside. Flush it with RV antifreeze before winter storage.
Details are on the AR North America site.
Shipping: Ships in 1 to 3 days via UPS.
How hot can the RGAHW4G40HN run?
Inlet water up to 180°F. Fit a thermal relief valve so water in bypass does not climb past that.
Which seal kit fits?
The AR42928 hot water seal kit, with AR2864 valves and AR2548 18 mm pistons.
What motor does it need?
AR rates the RGAHW4G40HN at 11 EBHP, so a 12 to 13 HP-class drive at 1750 RPM.