R6012 Electric Motor: 10 HP, 1750 RPM, 3-phase, 1-3/8 in. Solid Shaft
The R6012 is a 10 HP, 1750 RPM Annovi Reverberi electric motor with a 1-3/8 in. solid shaft on a NEMA 213T frame, with a standard foot-mount face with no bolt flange. A solid shaft gives you options: run the pump on belts and pulleys at its own rated speed, or couple it to the motor on a common base.
The enclosure is totally enclosed, fan cooled (TEFC) in black anodized aluminum, ready for wash bays and wet plant floors. The connector box is on the left, and the motor carries a 1.10 to 1.15 service factor.
| Specification | Value |
|---|---|
| Model | R6012 |
| Power | 10 HP |
| Voltage | 230/460 V |
| Phase | 3 |
| Frequency | 60 Hz |
| Full-load amps | 28 A at 230 V, 14 A at 460 V |
| Speed | 1750 RPM |
| Frame | NEMA 213T |
| Shaft | 1-3/8 in. solid |
| Mounting | Standard foot mount |
| Enclosure | TEFC, black anodized |
| Weight | 104 lbs |
Matching a Pump to the R6012
- Size the motor to the pump: GPM x PSI / 1,460 = HP needed at the pump, then leave 10 to 20 percent headroom. That puts pumps of up to roughly 8.3 to 9.1 HP on this motor.
- On a belt drive, size the pulleys so the pump turns at its rated RPM, not just at motor speed.
- Examples: the RRA4G30N, 4 GPM at 3,000 PSI, works out to 8.2 HP and the RKA4G30N, 4 GPM at 3,000 PSI, works out to 8.2 HP.
- For smaller pumps, the R6015 (7.5 HP) fits; for bigger ones, step up to the R6013 (15 HP).
Our guide on how to choose a pressure washer pump walks through sizing in more detail.
Care and Maintenance
- Keep the cooling fan and fins clear of dirt and overspray so the motor runs cool.
- Check belt tension and pulley alignment at every service.
- Keep the connector box cover and conduit entries sealed against washdown water.
Other 10 HP Options
The R6011 is the C-face version of this 10 HP motor, and the R2583A is a 10 HP hollow shaft motor that bolts straight to an AR pump. Not sure which fits? Text a specialist at (505) 226-6061 with your pump model. Details are on the AR North America site.
Shipping: Ships in 1 to 3 days via UPS.
What pumps does the R6012 fit?
Any pump up to about 8.3 to 9 EBHP on a belt drive or base-mounted coupling, such as the RKA4G30N.
Can the R6012 run on 230 V or 460 V?
Yes. The R6012 is a dual-voltage 3-phase, 60 Hz motor. Wire it for your supply: full-load current is 28 A at 230 V and 14 A at 460 V.
Do I need an electrician?
Yes. Have a qualified electrician fit motor protection and check rotation before running the pump under load.