AR46723 Stainless High Temperature Seal Kit for WHWL-SS, 28 mm
When a pump runs hot water or works through long shifts, the seals are the first thing to feel it. Heat takes the spring out of a standard compound: the lip hardens, stops following the plunger, and the pump starts weeping long before it has done the hours it should. AR46723 is the genuine Annovi Reverberi stainless high temperature seal set for 28 mm WHWL-SS pumps.
Check the Series and Plunger Size First
The AR46723 kit is 28 mm and belongs to the stainless WHWL-SS. Two things are easy to get wrong here. The standard WHW series, WHW2115N and WHW3220N, runs a 22 mm plunger and this kit will not fit it. And the 28 mm WHWL pumps, WHWL38.15N, WHWL50.15N and WHWL50.20NB, are not stainless. Read both the model designation and the plunger diameter off the pump tag before ordering the AR46723 set.
Why a High Temperature Kit
The AR46723 set exists because standard water seals are compounded for cold water duty. Put them behind a burner or a heat exchanger and they take a permanent set, go hard at the lip, and the machine starts losing pressure as it warms rather than when it is cold. A high temperature seal holds its shape and sealing force at elevated inlet temperature, so pressure stays flat through a long run and the seal reaches a normal service interval instead of half of one.
Signs It Is Time
- Leaks that show up once the water heats up
- Seals that come out hard, flattened or cracked
- Short seal life on a machine running standard seals
- Water weeping at the manifold on a hot water system
Tools You Will Need
- Seal pick to lift the old seals without scoring the seal bore
- Seal driver or a socket matching the seal outside diameter
- Clean pump oil or seal lubricant for the lips
- Torque wrench for the manifold bolts
Rebuild Tips
- Replace every seal in the AR46723 set together. A new seal beside a heat-hardened one will not last.
- Lubricate the seals before fitting and seat them square, never twisted.
- Inspect the pistons and piston guides while the manifold is off. Heat-damaged seals usually leave a scored plunger behind them.
- Check your actual inlet water temperature against the limit Annovi Reverberi publishes for the pump. A high temperature seal raises the ceiling; it does not remove it.
- Run up at low pressure, then bring the system to temperature and check for leaks again before returning it to full duty.
Order With It
The other WHWL-SS service parts are AR47538 valve kit, AR47539 water seal kit and AR42536 piston guide kit. Refill with AR64516 pump oil.
Key Specifications
- Part Number: AR46723
- Kit Type: Stainless high temperature seal kit
- Fits: WHWL-SS series
- Plunger Size: 28 mm
- Service: Hot water and high-duty
- Brand: Annovi Reverberi
- Part Origin: Genuine OEM










Reviews