Overview
14880RT30-UR-C — 30 ft GFCI 3/12 Cord Set | UL Listed Safety is a 30-foot, 3-conductor
12 AWG GFCI cord set engineered to deliver protected, grounded power to electric pressure washers and other
corded tools in wet or outdoor environments. By combining a ground fault circuit interrupter and a durable
power cable into one integrated assembly, it brings protection close to the load, eliminates extra adapters,
and keeps setups tidy so operators can focus on cleaning instead of managing extension cords.
The inline GFCI continuously monitors the balance between hot and neutral conductors and opens the circuit
rapidly when an imbalance indicates a fault path to ground—cutting power before a minor issue becomes a
serious hazard. UL listing verifies that the cord set has been evaluated against recognized standards for
performance and construction, supporting shop safety programs, audits, and fleet standardization.
14880RT30-UR-C Integrated GFCI Protection
- Inline ground fault protection: GFCI body sits in the cord, delivering protected, grounded
power all the way from the outlet to the washer. - Test & Reset buttons: clear, easy-reach controls make pre-use function checks quick
and repeatable—press Test to confirm the unit trips, then Reset to restore protection. - Fast fault interruption: trips rapidly when a ground fault is detected, reducing shock risk
in splash, spray, and washdown environments. - Productivity advantage: one cord handles both power delivery and GFCI protection, reducing
questionable connection points and helping crews launch jobs faster each shift.
Construction & Durability
- 3/12 AWG conductors: robust cross section sized for typical electric pressure washer loads
and common shop tools. - 30 ft working length: provides flexible reach from a protected outlet to the machine
without stacking multiple extension cords, helping maintain voltage stability. - Molded terminations with strain relief: withstand routine tugging, coil/uncoil cycles, and
light abrasion around carts, reels, and job sites. - Outdoor-rated jacket: designed to handle moisture, splash, and frequent handling around
wash bays and service areas.
Safe Use & Maintenance Practices
- Route the cord with gentle bends, away from sharp edges and pinch points under wheels or doors.
- Form a drip loop near the machine inlet so water on the jacket does not track into the washer or GFCI body.
- Place the GFCI module where indicators and buttons are visible and accessible but, when practical, shielded
from direct spray. - If the unit trips during use, pause to inspect cables, connectors, and the machine for moisture or damage
rather than repeatedly resetting. - Wipe the jacket clean so cuts or abrasions are easy to spot; check plug blades and receptacles for
discoloration or looseness and verify that strain reliefs remain intact. - Store loosely coiled to avoid hard kinks, and allow the cord to dry before stowing after heavy splash
exposure. - Perform periodic function tests with the Test and Reset buttons; replace the cord set if buttons stick,
indicators fail, or nuisance tripping persists under normal conditions.
Typical Applications 14880RT30-UR-C
- Electric pressure washers in vehicle rinse bays and detail shops
- Siding, deck, and patio cleaning with electric cold-water washers
- Equipment washdown and light indoor cleaning near floor drains
- General corded power tools used in damp or outdoor locations where ground fault protection is required
14880RT30-UR-C Key Specifications
- Model: 14880RT30-UR-C
- Length: 30 ft
- Conductors: 3-conductor, 12 AWG (3/12)
- Protection: Inline GFCI with Test / Reset
- Rating: UL listed, outdoor rated
summary: the 14880RT30-UR-C, GFCI cord set, 30 ft, 3/12 AWG, UL listed, electric pressure washer power,
ground fault protection, inline Test Reset, outdoor rated, durable jacket





Reviews
There are no reviews yet.