Annovi Reverberi XMA4G20E-F33 Triplex Pump | 4.0 GPM 2000 PSI F33 NEMA 56C 1750 RPM
XMA4G20E-F33 — the Annovi Reverberi Series 178 XMA commercial
triplex plunger pump delivering 4.0 GPM at 2,000 PSI at a
slow-speed 1,750 RPM through an F33 NEMA 56-C flange
and 5/8-inch hollow E-version electric shaft for direct coupling
to standard NEMA 56-C electric motors — engineered for fleet and equipment
washing, industrial maintenance wash stations, food processing facility washdown,
manufacturing cleaning systems, and commercial contractor electric rigs where
4.0 GPM high-flow output at 2,000 PSI from a compact, direct motor-driven
slow-speed platform delivers the combination of volume, pressure, and service
life that continuous commercial duty requires. At the heart of every
XMA4G20E-F33 is Annovi Reverberi’s dual redundant
packing system — the forged brass head double gasket sealing architecture
standard across the entire XM Series 178 family, deploying primary and secondary
packing stages so that early seal wear produces a telltale weep warning rather
than sudden pressure loss or crankcase contamination. Backed by a
5-year commercial warranty with AR North America’s nationwide
U.S.-based service centers and domestic WSHPWR fulfillment.
XMA4G20E-F33 Key Specifications
Performance, Drive & Construction — Confirmed AR Catalog
- Model: Annovi Reverberi XMA4G20E-F33
- Series: 178 (XMA) — Commercial
- Flow Rate: 4.0 GPM — highest flow in the
XMA F33 electric family; fast rinsing and
wide coverage for fleet washing, industrial
maintenance, and food
processing washdown - Maximum Pressure: 2,000 PSI — commercial
cleaning force for fleet vehicles, industrial
equipment, manufacturing surfaces, and
food processing
environments - EBHP: 5.5
- Operating Speed: 1,750 RPM — slow-speed
design for reduced heat, vibration, and
component wear in continuous-duty
commercial operation - Bore: 15 mm | Stroke:
approximately 17 mm - Weight: 14 lbs
- Shaft: 5/8-inch hollow E-version —
standard NEMA 56-C output shaft diameter - Flange: F33 NEMA 56-C — direct coupling
to compatible TEFC and standard NEMA 56-C
electric motors with 5/8-inch
output shaft - Packing System: Dual redundant —
primary and secondary stages standard across
all XM Series 178 pumps - Manifold: Forged brass
- Connecting Rods: Aluminum alloy
- Plungers: One-piece ceramic — heat,
abrasion, and thermal shock resistant - Valves: Stainless steel check valves
with maintenance plug access for
field serviceability - Crankcase: Die-cast aluminum with
heat-treated crankshaft, oversized bearings,
and oil-bath lubrication - Bearings: Oversized — sustained
1,750 RPM continuous-duty support - Inlet: 1/2-inch female |
Discharge: 3/8-inch female - Max Water Temperature: 140°F
- Oil Capacity: 14.5 oz
- Warranty: 5-year commercial —
U.S.-based service centers,
domestic WSHPWR fulfillment
Standard XM Series 178 Package
Every XMA4G20E-F33 Ships Complete — Nothing Extra to Source
Every pump across the AR XM Series 178 family ships with the same standard
factory package: break-in oil pre-filled in the crankcase,
vented dipstick for pressure control and oil level access,
oil sight glass for at-a-glance level checks before each
operating session, direct-drive mounting bolts for F33 NEMA
56-C motor installation, operator’s manual with parts schematic
for installation reference and repair kit identification, and
5-year commercial warranty documentation backed by AR North
America’s nationwide U.S. service center network and
domestic WSHPWR fulfillment.
The AR Dual Redundant Packing System
XMA4G20E-F33 — 60 Years of Longevity Engineering Standard on Every Unit
The dual redundant packing system is standard on every pump
across the AR XM, XMS, XMA, XMV, SXM, SXMS, SXMA, and SXMV triplex ceramic
plunger families. In a standard single-packing design, one seal ring contains
working pressure at every plunger stroke — when it wears, pressure bypasses
immediately, water contaminates the crankcase oil, and bearings accelerate
toward failure without warning. The AR dual redundant system places primary and
secondary packing stages in series. When the primary stage nears end of service
life, the secondary maintains pressure containment while a minor weep at the
telltale port alerts the operator. That early warning converts an unexpected
breakdown into a planned maintenance event — the accumulated result of over
60 years of Annovi Reverberi commercial pump engineering since 1958, and the
confidence behind the 5-year warranty on every XMA4G20E-F33.
4.0 GPM at 1,750 RPM — Highest-Flow XMA F33 Electric at Low Speed
More Volume Than the XMA3G25E-F33, Produced at the Same Controlled 1,750 RPM
The XMA4G20E-F33 is the highest-flow pump in the XMA F33
electric family — 4.0 GPM at 2,000 PSI versus the 3.0 GPM / 2,500 PSI of the
XMA3G25E-F33 above it in pressure, and 3.0 GPM / 1,800 PSI of the XMA3G18E-F33
below it. This positioning makes the XMA4G20E-F33 the correct choice when
maximum water volume at controlled 2,000 PSI is the priority over higher
pressure with less flow.
At 4.0 GPM, the XMA4G20E-F33 covers fleet vehicles,
industrial equipment, and food processing surfaces faster per shift than
3.0 GPM alternatives — moving loosened soils toward drains with fewer passes,
supporting more vehicles or equipment through a wash bay per operating hour,
and delivering the high-volume rinsing that food processing and manufacturing
washdown require to meet sanitation protocol timing. The 2,000 PSI working
pressure is effective on industrial surfaces, production equipment, and fleet
vehicles without the surface aggression that higher-pressure specifications
introduce in food processing and manufacturing environments where equipment
surfaces and coatings need protection.
All of this is produced at 1,750 RPM — the slow-speed
advantage that extends dual packing seal intervals, valve wear cycles, and
bearing service life versus the 3,400 RPM alternatives that deliver equivalent
or lower flow at higher speed-induced component fatigue. For industrial
facilities and fleet operations running the XMA4G20E-F33
through daily cleaning cycles, the 1,750 RPM design means predictable
maintenance scheduling that fits operational budgets rather than
emergency component replacement.
XMA4G20E-F33 Key Benefits
Highest-Flow XMA F33, Dual Redundant Packing, and Quiet Low-Speed Direct Drive
- Dual redundant packing — planned maintenance
instead of breakdowns: primary and secondary
stages with telltale port warning; standard on
every XM Series 178 pump since 1958 - 4.0 GPM — highest flow in the XMA F33
electric family: more volume for faster
fleet washing, broader industrial coverage,
and efficient food processing washdown than
the 3.0 GPM F33 variants at
equivalent or higher pressure - 2,000 PSI — effective commercial cleaning
without surface aggression: correct for
food processing equipment, manufacturing
surfaces, and fleet vehicles where
higher-pressure specifications
create surface risk - 1,750 RPM quiet low-speed operation:
cooler running, lower noise, and reduced
vibration versus 3,400 RPM alternatives —
the continuous-duty specification for
industrial wash stations where
ambient noise matters - F33 NEMA 56-C 5/8-inch E-shaft — standard
electric motor interface: fits the most
common NEMA 56-C motor output shaft without
adapters; compact direct coupling without
belts or pulleys - Forged brass manifold and field-serviceable
valves: maintenance plug access for AR repair
kit replacement — rebuilt at wear intervals,
not discarded
XMA4G20E-F33 Typical Applications
Where 4.0 GPM at 2,000 PSI at 1,750 RPM Delivers Commercial Results
- Fleet and equipment washing: trucks,
buses, and service vehicles where 4.0 GPM at
2,000 PSI delivers faster per-vehicle throughput
than 3.0 GPM alternatives — more vehicles
through the wash bay per shift - Industrial maintenance wash stations:
factory wash bays and production equipment
cleaning where 4.0 GPM high-flow output and
1,750 RPM quiet operation meet both throughput
and ambient noise requirements
of industrial facilities - Food processing facility washdown:
production floor and equipment cleaning where
4.0 GPM at 2,000 PSI covers large washdown
areas efficiently within sanitation protocol
timing — OEM system builders should follow
facility certification requirements
for completed system configurations - Manufacturing cleaning systems:
production and assembly environments where
consistent 4.0 GPM output from a compact
electric motor-driven platform meets facility
washdown requirements without
gas engine exhaust or
noise concerns - Commercial contractor electric rigs:
portable and cart-mounted systems where
the XMA4G20E-F33’s 4.0 GPM output,
F33 direct-drive, and 14-lb compact
weight deliver high-flow commercial
performance in a
manageable package
XMA4G20E-F33 Installation & Maintenance
Best Practices for Long Dual Packing Service Life at 1,750 RPM
- Confirm motor output shaft is 5/8-inch
and NEMA 56-C face: the XMA4G20E-F33
F33 E-shaft requires a 5/8-inch motor output
shaft — 3/4-inch shaft motors require a
D-version pump - Confirm motor delivers 1,750 RPM and
5.5 HP under load: motor undersizing
causes speed drop and reduces output
below 2,000 PSI - Monitor telltale port: minor weep =
primary packing wear; secondary is holding
pressure — schedule AR repair kit replacement
before secondary failure occurs - Install upstream inlet strainer:
50-mesh minimum — at 4.0 GPM clean inlet
water is critical; inadequate inlet sizing
causes cavitation that damages both
packing stages and
ceramic plungers - Size inlet plumbing for 4.0 GPM:
adequate supply line diameter prevents
inlet restriction cavitation — more
important at 4.0 GPM than at
lower-flow variants - Size unloader for 4.0 GPM and
2,000 PSI: prevents pressure spikes
that stress the dual packing beyond
rated load - Never run dry: confirm water flow
before starting — dry operation damages both
packing stages and plungers immediately
and voids warranty - First oil change at 50 hours:
then per AR duty-cycle schedule; flush manifold
with clean water after every
chemical application - Winterize: pump RV antifreeze
through or fully drain before freezing
temperatures — freeze damage
voids warranty
Why Choose the Annovi Reverberi XMA4G20E-F33
Maximum XMA F33 Flow at Controlled 2,000 PSI — Industrial Slow-Speed Commercial Performance
The XMA4G20E-F33 is the correct specification when maximum
flow volume at controlled 2,000 PSI from a standard NEMA 56-C 5/8-inch electric
motor is the priority — the highest-flow XMA F33 electric variant, delivering
4.0 GPM at 1,750 RPM slow-speed with dual redundant packing, forged brass
manifold, field-serviceable valves, and 60 years of Annovi Reverberi engineering
since 1958 behind every unit, backed by a 5-year warranty and AR North America’s
nationwide U.S. service infrastructure. Contact WSHPWR for current pricing,
availability, motor compatibility confirmation, and repair kit specification.





Reviews
There are no reviews yet.