Annovi Reverberi XHWASS3G15E-F33 Hot Water Stainless Triplex Pump | 3.0 GPM 1500 PSI 180°F PTFE
XHWASS3G15E-F33 — the Annovi Reverberi XHW series hot water
stainless steel triplex plunger pump delivering 3.0 GPM at 1,500 PSI
at 1,750 RPM with a NEMA 56C F33 direct-drive
flange — the only pump in the lineup rated for 180°F maximum
inlet water temperature, combining AISI 316 stainless construction,
PTFE (Teflon) seals, and 56C electric motor direct coupling for hot water
sanitation systems, steam-adjacent cleaning circuits, high-temperature chemical
rinse applications, and specialized OEM equipment where 140°F-rated pumps
cannot be specified. The XHWASS3G15E-F33 is the F33 electric
motor variant of the XHW hot water platform — NEMA 56C direct coupling at
1,750 RPM opens application possibilities that the standard 24 mm solid shaft
N version cannot serve, enabling compact electric motor-driven hot water
stainless pump integrations in food processing equipment, pharmaceutical
sanitation panels, mobile hot water cleaning units, and specialized OEM
machine builds where hot water capability, chemical resistance, and
space-efficient electric direct-drive are all required simultaneously.
The XHWASS3G15E-F33’s 40°F temperature advantage over
standard 140°F-rated pumps is not incremental — it opens a distinct set of
cleaning applications that lower-temperature pumps cannot serve. Hot water
at 160–180°F is the range where fat emulsification accelerates in food
processing, where pathogen reduction in dairy and poultry sanitation reaches
critical thresholds, where grease and hydrocarbon deposits liquefy on
industrial equipment, and where many approved sanitizers activate most
effectively. PTFE seals provide the chemical and temperature resistance
beyond what Viton and Buna-N offer in the most aggressive hot water and
solvent applications — PTFE is chemically inert across the broadest range
of industrial cleaning agents. Every XHWASS3G15E-F33 ships pre-filled with
break-in oil, factory performance-tested, and backed by a
5-year commercial warranty.
XHWASS3G15E-F33 Key Specifications
Performance, Drive & Hot Water Stainless Construction
- Model: Annovi Reverberi XHWASS3G15E-F33
- Series: XHW — Hot Water rated platform; the
only pump in the WSHPWR lineup rated for
180°F maximum water temperature - Flow Rate: 3.0 GPM — controlled output for
hot water sanitation systems, high-temperature chemical
rinse circuits, and OEM hot water
cleaning integrations - Maximum Pressure: 1,500 PSI — effective
hot water cleaning force for food processing equipment,
sanitation panels, and industrial washdown without
surface damage risk at
elevated temperatures - Operating Speed: 1,750 RPM — standard 4-pole
electric motor speed for direct NEMA 56C coupling without
additional speed reduction hardware - Maximum Water Temperature: 180°F —
the defining XHW specification; 40°F above the 140°F
limit of all other pumps in the lineup; enables hot water
fat emulsification, pathogen reduction threshold cleaning,
and solvent-compatible
hot rinse applications - Drive: F33 NEMA 56C flange with 5/8-inch
hollow shaft — direct coupling to standard TEFC electric
motors; AR part AR1780910; eliminates belts, pulleys,
and alignment procedures in compact
electric installations - Pump Type: Triplex plunger — three-cylinder
balanced design for smooth, low-pulsation output
at rated 1,500 PSI hot water operation - Pump Head: AISI 316 stainless steel —
corrosion and pitting resistance for chlorides, caustic
cleaning agents, sanitizers, and the elevated temperature
cycles of hot water
sanitation service - Seals: PTFE (Teflon) — chemically inert
across the broadest range of industrial cleaning agents;
the highest chemical and temperature resistance seal
specification in the lineup; superior to Viton and
Buna-N in the most aggressive hot water and
solvent applications - Plungers: Ceramic — dimensional stability
under thermal cycling and continuous stroking at 1,500 PSI
hot water operation - Valves: Stainless steel — corrosion resistance
and consistent sealing performance across hot water
chemical cycling - Bearings: Oversized — extended duty cycle
support at 1,750 RPM in hot water
continuous service - Inlet: 3/4-inch female |
Discharge: 3/8-inch female - Oil Capacity: 15 oz
- Oil Management: Oil sight glass and vented
dipstick for daily level checks in hot water
operating environments - Warranty: 5-year commercial warranty with
U.S.-based service support
What’s Included with the XHWASS3G15E-F33
Factory-Tested Hot Water Stainless Package for Immediate Installation
- Pre-filled break-in oil (15 oz) —
factory-installed for immediate commissioning
without sourcing initial oil fill - F33 NEMA 56C flange mount — integrated
for direct coupling to compatible 56C electric motors;
eliminates belt hardware
in compact installations - Oil sight glass — quick visual crankcase
level check before each operating session - Vented dipstick — crankcase pressure balance
and secondary level verification for routine
preventive maintenance - Full user manual and schematic — installation
reference, maintenance procedures, and parts
identification for the life of the pump - Factory performance documentation — verifies
3.0 GPM and 1,500 PSI output at 180°F rated
hot water specification - 5-year commercial warranty documentation —
with U.S.-based service support
The 180°F Advantage — Why Hot Water Rating Changes the Application
XHWASS3G15E-F33 — The Pump for Temperatures Standard Pumps Cannot Handle
Every other pump in the WSHPWR lineup is rated to 140°F maximum inlet water
temperature. The XHWASS3G15E-F33 is rated to 180°F — 40°F
higher, and that gap defines entirely different cleaning applications.
At 160–180°F, fat and grease deposits that resist cold and
warm water cleaning begin to emulsify and release from surfaces rapidly —
the thermal energy replaces or reduces the chemical energy required at lower
temperatures. Protein residues in meat and dairy processing facilities that
adhere strongly at 140°F become water-soluble and removable at 180°F.
Pathogen populations in food processing environments reach critical reduction
thresholds at these temperatures without relying solely on chemical sanitizer
concentration. Hydrocarbon deposits on industrial equipment liquefy. Many
approved food-contact sanitizers activate most effectively in the 160–180°F
range.
The PTFE seals are specifically chosen for this operating
range — PTFE (Teflon) is chemically inert across a broader range of industrial
cleaning agents and temperatures than Viton or Buna-N. In hot solvent
applications, aggressive degreaser concentrations at elevated temperature,
and specialty chemical circuits where even Viton compatibility cannot be
assumed, PTFE is the correct seal specification. Combined with the AISI 316
stainless head, the XHWASS3G15E-F33’s complete wet end is specified for
the most demanding intersection of temperature and chemical exposure
in the commercial cleaning pump class.
The F33 NEMA 56C electric direct-drive mount is what makes
the hot water XHW platform accessible for the applications where engine-driven
versions are not practical — enclosed food processing sanitation panels,
pharmaceutical washdown equipment, laboratory hot rinse systems, and OEM
medical equipment cleaning circuits all require electric motor operation.
The F33 flange makes the XHW’s 180°F hot water capability available
in a compact electric package.
XHWASS3G15E-F33 Creative Application Possibilities
Where 180°F Electric Hot Water Stainless Capability Opens Unique Solutions
- Enclosed food processing CIP satellite stations:
compact NEMA 56C electric motor-driven hot water rinse
points installed directly at processing equipment
locations — the F33 direct-drive keeps the
XHWASS3G15E-F33 small enough to mount on
stainless equipment frames beside the
processing point it serves - Pharmaceutical and biotech hot water cleaning
circuits: 180°F hot water at 1,500 PSI in
AISI 316 stainless with PTFE seals meets the material
and temperature specifications of pharmaceutical
equipment cleaning protocols — the F33 electric mount
integrates cleanly into enclosed pharmaceutical
equipment panels - Medical and dental equipment sterilization
rinse systems: hot water rinse circuits in
medical equipment where 180°F, PTFE chemical inertness,
and stainless construction are all specified for
the cleaning application — the compact F33
electric form factor fits enclosed
medical equipment cabinets - Mobile hot water chemical cleaning trailer
rigs: pair the XHWASS3G15E-F33 with a
compact electric generator and stainless hot water
tank for a self-contained mobile hot water stainless
cleaning system where the 56C motor mount
eliminates gas engine complexity and
exhaust in enclosed spaces - Commercial kitchen and restaurant hood degreasing
systems: hot water at 160–180°F with PTFE seals
in a compact electric motor-driven package for
professional hood and duct cleaning contractors —
180°F accelerates grease emulsification and
reduces degreaser chemical requirement
per cleaning cycle - Dairy and poultry processing hot sanitizer
circuits: dedicated hot sanitizer delivery
stations where the XHWASS3G15E-F33’s 180°F rating,
AISI 316 manifold, and PTFE seals handle both the
temperature and the chemistry of approved
hot sanitizer concentrate
applications - Winery and brewery hot water CIP feed
pumps: 180°F hot water for vessel, line, and
equipment CIP circuits in beverage production where
stainless construction and PTFE chemical inertness
handle caustic CIP chemistry at elevated
temperatures without seal
compatibility concerns - Printed circuit board and precision parts
cleaning systems: hot water with controlled
1,500 PSI and 3.0 GPM for electronics and
precision component cleaning where the
XHWASS3G15E-F33’s compact F33 electric mount,
PTFE chemical inertness, and controlled flow
minimize overspray on sensitive
adjacent components
XHWASS3G15E-F33 Key Benefits
180°F, PTFE, AISI 316, and F33 Direct-Drive — The Most Specified Hot Water Stainless Package
- 180°F — the specification that defines the
application class: 40°F above every other pump
in the lineup; the temperature at which fat emulsification
accelerates, pathogen reduction thresholds are reached,
and grease deposits liquefy — the XHWASS3G15E-F33
is built for the temperatures that define
serious sanitation cleaning - PTFE — the highest chemical resistance seal
in the lineup: chemically inert across a broader
range of industrial cleaning agents and temperatures
than Viton or Buna-N — the correct seal for hot solvent
applications, aggressive degreaser concentrations,
and specialty chemical circuits where even Viton
compatibility cannot be assumed - AISI 316 stainless with PTFE — the complete
hot water chemical resistance package: manifold
and seal together specified for the most demanding
intersection of temperature and chemical exposure
in the commercial pump class - F33 electric mount brings 180°F to enclosed
applications: the NEMA 56C direct-drive makes
XHW hot water capability available in food processing
panels, pharmaceutical equipment, laboratory circuits,
and medical OEM builds where engine-driven
platforms are not acceptable - Compact electric form factor for OEM
integration: F33 direct coupling in a compact
stainless package — fits enclosed equipment cabinets,
stainless frames, and OEM machine builds where
hot water pump space allocation is
tightly constrained - 3/4-inch female inlet for hot water supply
sizing: larger inlet thread than the standard
1/2-inch XMA series — accommodates the higher flow
velocity and thermal expansion of
180°F hot water supply plumbing - 5-year warranty on the XHW hot water stainless
platform: exceptional coverage for the most
specified pump in the lineup — backed by U.S.-based
service support - Backed by WSHPWR: expert hot water system
application support, PTFE chemical compatibility guidance,
motor compatibility confirmation, and full parts
availability for the XHWASS3G15E-F33 and the
complete Annovi Reverberi XHW
hot water pump family
XHWASS3G15E-F33 Installation & Maintenance
Critical Best Practices for 180°F Hot Water Stainless Electric Systems
- Verify all system components are rated for
180°F: the XHWASS3G15E-F33 handles 180°F —
every downstream component including hoses, fittings,
unloader, spray gun, and lance must also be rated
for 180°F hot water service; standard 140°F-rated
hose assemblies are not acceptable in
this system - Use 3/4-inch inlet plumbing for hot water
supply: the larger 3/4-inch female inlet
is sized for hot water supply lines — do not restrict
the inlet with undersized plumbing that creates
cavitation at hot water
operating temperatures - Install thermal-rated filtration upstream:
inlet strainer must be rated for 180°F service —
standard plastic strainer bodies deform at elevated
temperatures; use metal or high-temperature
rated filtration hardware - Verify NEMA 56C motor compatibility and
thermal rating: confirm the electric motor
is NEMA 56C face configuration and rated for the
ambient temperature conditions of the hot water
installation environment - Confirm PTFE chemical compatibility at
operating temperature: PTFE is broadly
chemically inert but always verify specific cleaning
agent compatibility at actual concentration and
operating temperature before commissioning
the XHWASS3G15E-F33 - Size unloader for hot water service:
rate unloader for 1,500 PSI, 3.0 GPM, and 180°F
water temperature — standard unloaders may not
be rated for 180°F bypass water
temperature - Manage bypass water temperature
carefully: at 180°F, extended bypass cycles
recirculate very hot water — route bypass to tank
and monitor inlet temperature to prevent heat
accumulation that exceeds the pump’s
rated maximum - Never run dry: confirm water flow
before starting — dry operation at any temperature
damages PTFE seals and ceramic plunger packings
immediately and voids warranty - Check oil before every shift:
hot water operation increases thermal load on the
crankcase — adequate oil is critical for bearing
protection at 1,750 RPM in
hot water service - Flush with cool water before shutdown:
run cool water through the XHWASS3G15E-F33 for
30–60 seconds before stopping to reduce
manifold temperature before the pump
enters idle thermal soak
Why Choose the Annovi Reverberi XHWASS3G15E-F33
The Only 180°F Electric Hot Water Stainless Pump in the Lineup
- Nothing else in the lineup does what the
XHWASS3G15E-F33 does: 180°F rated, PTFE sealed,
AISI 316 stainless, F33 NEMA 56C electric direct-drive —
no other pump in the WSHPWR catalog combines all four
specifications in a single
compact package - The temperature that changes sanitation
outcomes: 180°F is not just hotter — it is the
operating range where fat emulsification, pathogen
reduction thresholds, and grease liquefaction happen
at rates that lower-temperature systems
cannot achieve - PTFE above Viton above Buna-N — the complete
chemical resistance hierarchy: the
XHWASS3G15E-F33 sits at the top of the seal
compatibility hierarchy for the most aggressive
hot chemical environments where
Viton is not enough - Electric F33 mount opens enclosed
applications: hot water pump capability
in food processing panels, pharmaceutical equipment,
medical OEM builds, and laboratory systems where
gas-engine XHW versions cannot be specified - Annovi Reverberi XHW hot water engineering
since 1958: over 60 years of industrial pump
manufacturing expertise in hot water pump design for
food processing, pharmaceutical, and industrial
high-temperature applications - 5-year warranty on the most specified
configuration in the lineup: exceptional
coverage for a premium hot water stainless pump —
backed by U.S.-based nationwide
service support - Backed by WSHPWR: expert hot water
system design support, downstream component
temperature rating guidance, PTFE compatibility
verification, and full parts availability for the
XHWASS3G15E-F33 and the complete Annovi Reverberi
XHW hot water pump family
The XHWASS3G15E-F33 delivers 3.0 GPM at 1,500 PSI
at 1,750 RPM with a 180°F maximum water temperature rating
through a NEMA 56C F33 direct-drive flange built on an
AISI 316 stainless head with PTFE seals — the only hot water
electric stainless pump in the WSHPWR lineup, engineered for food processing
sanitation panels, pharmaceutical hot rinse circuits, commercial degreasing
systems, winery and brewery CIP feeds, and specialized OEM hot water cleaning
equipment where 180°F capability, PTFE chemical inertness, and compact NEMA 56C
electric integration are all required simultaneously. Contact WSHPWR for current
pricing, availability, downstream component temperature rating guidance, and
hot water system design support.





Reviews
There are no reviews yet.